Manufacturer by Type

Products by Category



Gwinstek LCR-915 LCR Meters

PDFPrintEmail
The LCR-915 is a smart, convenient and fully-functional dual display handheld LCR meter. The test frequency extends as high as 10 kHz, providing greater flexibility to test a wider range of components.
Price:
Manufacturer: GWInstek
Description

The LCR-915 is a smart, convenient and fully-functional dual display handheld LCR meter. The test frequency extends as high as 10 kHz, providing greater flexibility to test a wider range of components. The LCR-915 uses a dual 20,000/2000 count display. The 20000 count display is used for displaying primary parameters such as capacitance, inductance, reactance and resistance and a 2000 count display is for secondary parameters such as Q, D, θ,ESR and RP measurements. Secondary measurements can also be combined with the primary measurement while the primary measurement is still being taken.

Features:

     20,000/2,000 Counts Dual Display

     Test Frequency : 100/120Hz/1/10kHz

     Auto LCR Mode for DUT Measuring

     0.2% Basic Accuracy

     Measurement Parameter : L,C,R,D,Q,ESR,θ,DCR

     Parallel/Series Testing Mode

     Sorting Mode for Quality Control

     2Wire or 5Wire Measurement Available

     Data Hold and Zero Mode Supported

     Auto Range, Auto Backlit

     Low Battery Indication

     Auto Power off

     Data Collection or AC power operation (Optional)

Specification:

TEST FREQUENCY
  100Hz/120Hz/1kHz/10kHz Selectable
FULL SCALE
Main Display 20,000/2,000 count Selectable
Sub Display 2,000 count
INDUCTANCE (L)
Range 20uH ~ 20kH depends on the selected test frequency
Best Accuracy +(0.2% rdg + 2 digits)
Resolution 0.001uH ~ 0.001kH depends on the selected range
CAPACITANCE (C)
Range 20pF ~ 20mF depends on the selected test frequency
Best Accuracy +(0.2% rdg + 2 digits)
Resolution 0.001pF ~ 0.001mF depends on the selected range
RESISTANCE (R)
Range 20Ω ~ 200MΩ depends on the slelcted test frequency
Best Accuracy +(0.2% rdg+ 2 digits)
Resolution 0.001Ω ~ 0.01MΩ depends on the selected range
DC RESISTANCE (Rdc)
Range 200Ω ~ 200MΩ depends on the slelcted test frequency
Best Accuracy +(0.2% rdg+ 2 digits)
Resolution 0.01Ω ~ 0.01MΩ depends on the selected range
QUALITY FACTOR (Q)
Range 0.000 ~ 999
Accuracy 2 x (main parameter accuracy)
Best Resolution 0.001
DISSIPATION FACTOR (D)
Range 0.000 ~ 999
Accuracy 2 x (main parameter accuracy)
Best Resolution 0.001
PHASE ANGLE (θ)
Range -90° ~ 90°
Accuracy +(0.2% rdg+ 5 digits)
Resolution 0.1°
MEASUREMENT CIRCUIT
  Parallel or Series Selectable
AUTO LCR MODE
  Automatically identifies and measures the DUT when the meter is switch on
SORTING MODE
  +0.1%, +0.2%, +0.25%, +0.5%, +1.0%, +2.0%, +5.0%, +10.0%, +20.0%, +80%/-20% Selectable
OTHER FUNCTIONS
  Auto range, Auto backlit, Data hold, Zero, Auto power off, 46 segments analogue bar
DISPLAY
  LCD mono display
INTERFACE
  USB
POWER SOURCE
  AA Battery 1.5V x 4
  DC 5V(through AC adapter or USB cable) - Optional
DIMENSIONS & WEIGHT
  95(W) × 207(H) × 52(D) mm
Approx. 630g